Actuator: Roller lever (Metal lever, resin roller).
Cable length: 3 m.
Pull-outing direction of cable: Vertical.
Built-in switch: 1NC/1NO (slow-action) DRT2-ID16-1 PDF.
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model).
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available
DRT2-ID16-1
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Type: Welding / wire type, with right column DRT2-ID16-1 PDF.
Driving rod: swing lever type.
Terminal specification: welding.
Contact specifications: 1c.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment DRT2-ID16-1 PDF.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Specifications: Innputs; NPN (+ common);
16 points DRT2-ID16-1 Manual.
I/O connections: M3 screw terminals.
Rated internal circuit power supply voltage:
Supplied from Basic Unit OMRON INSTRUCTION Manual.
I/O power supply voltage: 24 VDC.
A Smart Slave with a 3-tier Terminal,
Block That Means Wiring Locations,
Are Easy to Understand with No,
Sharing of Terminals.
Easy wiring with no sharing of terminals.
Easy-to-understand wiring locations OMRON INSTRUCTION Manual.
No relay terminal block terminals required.
Detachable cassette-type circuit sections. Ratings: 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable*.
Actuator: Roller plunger.
Cable length : 3m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard) OMRON INSTRUCTION Manual.
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cablee lengths of 3 and 5 m available on standard models DRT2-ID16-1 INSTRUCTION Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
conffirmation of operation DRT2-ID16-1 Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)