Size: M12 (Brass); Single; Unshielded.
Sensing distance: 10 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: NPN E2FM-X2C2 PDF.
Operation mode NC.
A new generation in global applications. Slit width: Width 0.5 × 10 mm.
Installation procedure: Plug-in type.
Applicable type: E3Z-T@@. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V)
E2FM-X2C2
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E2FM-X2C2 PDF.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E2FM-X2C2 PDF.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive displayy PV/SV E2FM-X2C2 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay OMRON INSTRUCTION sheet. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: -- OMRON INSTRUCTION sheet.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function OMRON INSTRUCTION sheet.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2FM-X2C2 INSTRUCTION sheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E2FM-X2C2 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.