Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 20cm.
Lead wire type: Heat resistive .
Lead wire length M : 1m E5CN-Q2TDU PDF.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers
E5CN-Q2TDU
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CN-Q2TDU PDF. The ultra small size, high performance and rich models.
5.5mm ultra small built-in amplifier.
Maximum detection distance 2.5mm. Workpiece shaking can also be stable detection.
Response frequency 1kHz.
Low consumption current.
Category: DC 3 wire type.
Shape: non shield.
Detection surface: below E5CN-Q2TDU PDF.
Detection range: 2.5mm.
Output form: NPN.
Action mode: NO. E3JM-R4M4T detection method: Regression reflection type with M.S.R. function,
Connection: terminal plate,
Detection range: 4m.
Output status: ON into the light; light shading ON; switch conversion type.
Output: relay. Function: timer,
2 types of cost reductionSize: 96 × 96 mm OMRON INSTRUCTION Manual.
Control type: 4-loop control.
Control mode: 4-loop standard coontrol,
2-loop heating and cooling control (See note 2 E5CN-Q2TDU Manual. ).
Outputs(control/transfer): 4 (4 current).
Optional functions: Auxiliary outputs (SUB), 10 (See note 1.);
Event inputs, 8; Serial communications, RS-485 OMRON INSTRUCTION Manual.
A new High-speed, High-precision Digital.
Controller that is Programmable!
Create up to 32 programs with up to 256 segments total.
Coordinated operation for up to four channels with one Digital Controller.
0.01°C High resolution for Pt input.
High-speed sampling at 50 ms OMRON INSTRUCTION Manual.
Settings easily made from a computer using the CX-Thermo.
RoHS compliance for world-wide application. Size: 48 x 48mm.
Control output 1: relay.
Auxiliary (alarm) output: 3.
Transfer output: -.
Event input: 2.
Communication: -.
Disconnection detection: 1.
Power supply voltage: AC100 ~ 240V.
The white PV (current value) with excellent visibility shows the segment to make the confirmation work more easily.
Eye-catching white + industry''s largest display size
The black and white display and the industry''s largest display size to achieve excellent visibility.
No matter from which angle or in the natural lighting environment, the dark scene,
Can quickly and accurately confirm the current value E5CN-Q2TDU INSTRUCTION Manual.
Displays the current value (PV/ white), the target value (SV/ green) and the progress of tthe program (PRG, SEG/ yellow) E5CN-Q2TDU Manual.
Can be viewed at the same time, there is no need to switch the display, so as to improve the efficiency of operations.