Sensing method: Retro-reflective with MSR function.
Connection method: Pre-wired (2 m).
Response time: 1 ms.
Sensing distance: 15 m (300 mm) (Using E39-R1),
7 m(200 mm)(Using E39-R12), 7 m (200 mm)(Using E39-R6) E5CN-QTDU PDF.
Model: PNP output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC).
Product lineup includes models with distance setting without,
influence of color
E5CN-QTDU
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class. Type: high temperature.
Measuring temperature range: 0 ~ +1000.
The target size: 40mm diameter (from 500mm) E5CN-QTDU PDF.
No need to contact the workpiece, you can measure the temperature.
Achieve no damage, health and efficient temperature management.
A small spot diameter 3mm and 8mm diameter two types.
Reproduction of positive and negative 0.5 degrees Celsius, response speed of 0 E5CN-QTDU PDF. 4 seconds,
(95%) with high precision and high speed measurement.
In addition to the original middle temperature (0 ~ +500 C),
Also added in low temperature (- 50 DEG C ~ +500),
High temperature (0 ~ +1000 degrees C) models.
New measurement distance up to 500mm, 1000mm long distance type.
Use another programmer, can change the temperature moniitoring, radiation rate,
Moving average function and output range OMRON INSTRUCTION Manual E5CN-QTDU Manual.
(picture for the installation of programmer in the ES1 body)
Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1 OMRON INSTRUCTION Manual.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance OMRON INSTRUCTION Manual. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5CN-QTDU INSTRUCTION Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5CN-QTDU Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.