Power supply voltage: 12 to 24 VDC.
Output configuration: NPN open collector.
Output code: BCD.
Resolution (divisions): 360.
Connection method: Pre-wired Model E5CS-Q1KJX PDF.
Rugged Rotary Encoder.
Absolute model.
External diameter of 60 mm.
Resolution of up to 1,024 (10-bit).
IP65 oil-proof protection.
Strong shaft.
Radial: 120 N, Thrust: 50 N. Temperature range: -20.0 ~ 60.
Digital thermometer for replacing alcohol thermometer
E5CS-Q1KJX
With the aid of microcomputer, high precision can be realized (with 0.1 degree C as the unit).
Built in battery, no power supply connection.
Large LCD (character height 12mm) digital display E5CS-Q1KJX PDF. Item: Mark-detecting models(multiple color light sources); Green LED.
Functions: Timer, Response speed change.
Model: PNP output.
Advanced Fiber Amplifier Units.
Features a Power Tuning function that optimizes light,
reception at the press of a button.
APC circuits to suppress LED aging degradation used with,
4-element LEDs E5CS-Q1KJX PDF.
2-channel models achieve the thinnest* profile in the industry,
at only 5 mm per channel.
2-channel models also offer AND/OR control output.
The E3X-MDA0 with two channels supports an EtherCAT Sensor.
Communications Unit or CompoNet Sensor Communications Unit OMRON INSTRUCTION Manual. Appearance: --.
Sensing method: Through-beam type (with slot).
Sensing distance: 3.6 mm (slot width).
Output type: NPN output.
Output configuration: Light-ON.
Photomicrosensor with light,
modulation is not influenced by,
external light.
Voltage-ouutput models with wide operating voltage,
range (5 to 24 VDC) OMRON INSTRUCTION Manual E5CS-Q1KJX Manual.
Fitted with an easy-to-adjust optical axis mark.
Easy adjustment and optical axis monitoring with,
a light indicator. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1 OMRON INSTRUCTION Manual.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of tthe Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5CS-Q1KJX INSTRUCTION Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5CS-Q1KJX Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.