Brand: OMRON
Product model: E5CS-QG
Name: temperature controller
Sort: INSTRUCTION Manual
File language: English
File size: 0.63MB
Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output E5CS-QG PDF.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (using control output) E5CS-QG
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E5CS-QG PDF.
Add PV/SV state display function, to see the state of the tthermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E5CS-QG Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E5CS-QG PDF.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. The main body: terminal type, temperature input type OMRON INSTRUCTION Manual.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use OMRON INSTRUCTION Manual.
Event input points: -.
Transfer output: output (using control output).
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improovement OMRON INSTRUCTION Manual E5CS-QG INSTRUCTION Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5CS-QG Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Digital temperature controller
E5CC-RX3DSM-003
OMRON Digital temperature controller E5CC-RX3DSM-003
Size: 48 x 48mm. Control output 1: relay out
OMRON
Digital Temperature Controllers
E5CZ-R2TU
OMRON Digital Temperature Controllers E5CZ-R2TU
Size: 1/16 DIN. Power supply voltage: 100 to
OMRON
Programmed temperature controller
E5CN-HTV2BF
OMRON Programmed temperature controller E5CN-HTV2BF
Size: 48 48mm, terminal type. Category: con
OMRON
High performance temperature controller
E5CN-HR2H01D-FLK
OMRON High performance temperature controller E5CN-HR2H01D-FLK
Size: 48 x 48mm. Body: terminal type. Type: c