Type: Cable with Connectors on Both Ends (RJ45/RJ45).
Category: Cat.5 .
Cable sheath material: PUR.
Cable color: Green.
Cable length: 1 m.
Cables and Connectors for,
EtherCAT® and Other Industrial,
Ethernet Networks XWT-OD16-1 PDF. Type: Normal wiring.
Cable length L: 1.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch
XWT-OD16-1 Sensor type and connection: 3 line DC (NPN) /2 line 3-4.
Actuator connection: actuator connection 1-4.
Port number: 4.
Cable length: 5m.
This series contains the optimal control case of the new thin,
Light connector terminal box, has better,
Environmental resistance and centralized management of I/O sensor connector,
Therefore, less artificial XWT-OD16-1 PDF.
Wear resistant thin, protection grade can reach IP67.
Suitable for photoelectric sensor,
Proximity sensor and sensor with I/O connector (M12) limit switch.
In addition, due to the increase of the rated current, the ground terminal is increased,
So it can support and connect the valve solenoid XWT-OD16-1 PDF.
Contains power and action indicator light.
No matter how many ports are used, the installation method is used,
To ensure that the system can be easily expanded OMRON INSTRUCTION Manual. Suitable cable dia: 4 mm dia. model (4 to 5 mm dia.).
Suitablle core size: 0 XWT-OD16-1 Manual. 5 max.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: L-shaped.
Connection method: Soldering.
AC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort OMRON INSTRUCTION Manual.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on OMRON INSTRUCTION Manual.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Cable Specifications: Fire-retardant, Robot cable.
Cable connection direction: Straight.
Cable diameter: 6.0 mm dia.
No. of cable cores: 3.
Cable core cross sectional area: 0.5 mm.
Cable length: 5 m.
DC.
Minimum order: 5.
UL-listed: Yes.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ennsure a,
94V-0 fire retardant rating XWT-OD16-1 INSTRUCTION Manual.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of CConnector Assembly: Crimping, soldering, and screw-on XWT-OD16-1 Manual.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202.