LK166
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI AJ35PTF-28AS datasheet PDF

MITSUBISHI AJ35PTF-28AS datasheet PDF

Brand: MITSUBISHI
Product model: AJ35PTF-28AS
Name: AC input / silicon controlled output module
Sort: PDF datasheet
File language: English
File size: 7.99MB
Cable length: 1.2 meters.
Extending cable to connect CPU main substrate and extended substrate,
According to the model can provide different cable length,
If you need to connect the AnN type expansion substrate is required,
Selection of A1SC05NB (A1SC07NB) cable. Analog channel: 4 channels.
Input / output (resolution): 0 ~ 4000 AJ35PTF-28AS PDF.
Conversion speed: 100ms/4 channel.
Analog module installation AJ35PTF-28AS
Power supply: AC170V ~ 264V.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system AJ35PTF-28AS PDF.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong AJ35PTF-28AS PDF.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. Input channel number: 4.
Output channel number: 2.
Occupy I/O points: 64.
A1S63ADA analog input / output combination components can be analog / digital / digital / analog conversion,
The input and output signals can be voltage or current,
Offset and gain can be set and stored.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and thhe time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on AJ35PTF-28AS datasheet AJ35PTF-28AS datasheet.
This phenomenon is called the I/O delay time effect.
Related products
MITSUBISHI
DC input / silicon controlled output module
AJ35PTF-56DS
MITSUBISHI DC input / silicon controlled output module AJ35PTF-56DS
DC input points: 32 points. Input voltage and
MITSUBISHI
DC input / transistor output module
AJ35PTF-128DT
MITSUBISHI DC input / transistor output module AJ35PTF-128DT
DC input points: 64 points. Input voltage and
MITSUBISHI
DC input / transistor output module
AJ35PTF-56DT
MITSUBISHI DC input / transistor output module AJ35PTF-56DT
DC input points: 32 points. Input voltage and
MITSUBISHI
Transistor output module
AJ35PTF-24T
MITSUBISHI Transistor output module
 AJ35PTF-24T
Output points: 24 points. Output voltage and