MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 7.5KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible FR-AAT PDF
FR-AAT
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-AAT PDF.
The inverter power supply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft. Input output cable for A6TBXY36 type connector / terminal row conversion module.
Length 1.5M. MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 18.5KW.
FR-A700 converter products are suitable for all kinds of high load requirements of the equipment FR-AAT PDF.
Such as lifting, lift, printing and dyeing, printing and dyeing, material coiling and other general occasions.
High level driving performance.
Unique sensorless vector control mode,
A wide variety of mechanical equipment can be operated at high precision in the super low speed region without the need of the encoder.
With torque control mode,
And in the speed control mode can use the torque limit function.
With vector control function (with encoder),
Frequency converter can achieve position control and fast response, high precision speed control (zero speed control, servo lock, etc.) and torque control. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 45KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes.
For the requirements of relatively high precision, even if the load cchanges are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection) FR-AAT datasheet.
If the given acceleration time is too short, the output frequency of the inverter is far more than thhe change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall FR-AAT datasheet.