MITSUBISHI L6ADP-R2-CM datasheet PDF

Brand: MITSUBISHI
Product model: L6ADP-R2-CM
Name: RS-232 adapter
Sort: PDF datasheet
File language: English
File size: 12.21MB
"Universal output function: leakage type.
Program capacity: 260K step.
Basic operations processing speed: 9.5ns.
Communication interface: USB/Ethernet.
Program capacity: 20K step.
Control mode: stored procedure repeated operation.
Input / output points: 4096 points.
End cap.
High precision PWM control of the highest 200kHz L6ADP-R2-CM PDF.
In the PWM output mode, by setting the ON time and cycle time,
The duty cycle can be changed, and the minimum cycle time is 5 s L6ADP-R2-CM
In addition to lighting dimming control, simple motor control and heater control,
Can also be used to require high resolution detection equipment, such as a wide range of oscillators.
CPU built-in functions can be easily set through programming tools L6ADP-R2-CM PDF.
The built-in I/O function settings can be easily carried out through the parameters of the programming tool.
5 s units can be used for high precision workpiece measurement in pulse measurement mode,
Can be used with a minimum of 5 s units of the input signal of the ON/OFF time (the shortest 200 s) for high precision measurement.
For example, after measuring the ON time of the sensor input,
The "moving speed" and "length" of the workpiece can be accurately calculated " L6ADP-R2-CM PDF. "Thermocouple input.
Number of input channels: 4ch.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling.
According to the object device can choose any one of the following control method.
Standard control (heating or cooling).
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost L6ADP-R2-CM datasheet.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniiform, to ensure that the control object no local burning or thermal expansion L6ADP-R2-CM datasheet.
No idle running, with energy saving effect, can reduce operating costs.
Related products
MITSUBISHI
RS-422/485 adapter
L6ADP-R4-CM
MITSUBISHI RS-422/485 adapter L6ADP-R4-CM
Maximum transmission speed: 115.2kps. DC5V i
MITSUBISHI
RS-232 adapter
L6ADP-R2-CM
MITSUBISHI RS-232 adapter L6ADP-R2-CM
Maximum transmission speed: 115.2kps. DC5V i
MITSUBISHI
Serial communication module
LJ71C24-R2-CM
MITSUBISHI Serial communication module LJ71C24-R2-CM
RS-232. Transmission speed: 230.4kps. MC pro
MITSUBISHI
Contact output module
LY10R2-CM
MITSUBISHI Contact output module LY10R2-CM
Output points: 16 points. Rated output voltag