Maximum transmission speed: 115.2kbps.
DC5V internal consumption current: 0.15A.
Weight: 0.12kg.
GOT connection.
MELSOFT connection.
Communication protocol support function serial communication function.
DC5V internal consumption current: 0.08A.
Weight: 0.13kg.
1 the field input interface module is composed of an optical coupling module and an input interface module of the microcomputer,
Function is the interface of the programmable logic controller and the field control.
2 the field output interface module is integrated with the output data register, the gating module and the interrupt request module,
The programmable logic controller outputs the corresponding control signal to the execution part of the field through the field output interface module MITSUBISHI L6ADP-R4-CM
L6ADP-R4-CM Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.Can be used as a screw relay terminal MITSUBISHI L6ADP-R4-CM. Negative common end useThermocouple input.
Number of input channels: 4ch.
Detection function of broken wire with heater.
Standard control.
Heating and cooling control.
Self tuning function.
Peak current suppression.
Heating function at the same time.
Sampling period switching function.
Temperature input mode.
Temperature regulation mode.
To reduce operating costs by saving energy
Peak current suppression
After the peak current suppression function is used, the number of the upper limit output limit of each channel can be changed automatically,
Split transistor output time MITSUBISHI L6ADP-R4-CM. To suppress the peak current.
Restrain the peak current to achieve energy saving effect (reducing the power supply capacity of the equipment, saving the electricity contract), and reduce the operation cost.
Achieve average temperature control
Warming function at the same time
By making the arrival time of the multi loop consistent, uniform temperature control function.
It can control temperature uniform, to ensure that the control object no local burning or thermal expansion.
No idle running, with energy saving effect, can reduce operating costs.
To achieve high stability temperature control
Standard control / heating, cooling control.
The device used for the temperature control of the temperature control of the extrusion molding machine can prevent over heating and cooling L6ADP-R4-CM.
According to the object device can choose any one of the following control method.
Standard controol (heating or cooling) L6ADP-R4-CM.
Heating, cooling control (heating and cooling).
Hybrid control (combination of standard control and heating, cooling control).