Output points: 32 points.
Output form: Transistor (drain type) output.
Rated open and close voltage, current: -.
Rated load voltage: DC12 ~ 24V.
Max load current: 0.2A/ point.
Response time: 1ms.
Common way: 32 point / public end.
Protection function (overload, overheat).
External wiring connection mode: 40 pin connector R120SFCPU-SET PDF.
Output module with mechanical relay contact mechanism,
Including the load voltage range of the relay and can be used for the output of the DC12~24V load transistor output type
R120SFCPU-SET
According to the load voltage, the output points of different, choose the most suitable user needs of the module.
Preventive maintenance based on the life of relay contact.
Relay output module can accumulate the number of ON of each output point R120SFCPU-SET PDF.
Through the understanding of the relay contacts of the number of times, according to the relay life of preventive maintenance. 230.4kbps Max., RS-422/485 2 channel.
When using the serial communication module, it is only necessary to select from the communication protocol library of engineering software,
Can carry out data communication support MODBUS general agreement R120SFCPU-SET PDF.
2 channels are supported 230.4kbps, communication can fully play the performance of the matching equipment. Analog input channel number: 8CH.
Cold end compensation precision.
Available thermocouple: -.
Available temperature resistance: Pt100, JPt100, Ni100, Pt50.
Resolution: 0.1.
Conversion speed: 10ms/CH.
Insulation between channels: isolation transformer insulation.
Disconnection detection: there.
External wiring connection mode: 40 pin connector.
output
The temperature measurement value (16 bit''signed binary): 2000 ~ 8500.
Zoom value (16 bit with symbol binary).
No program can perform conversion operations, scaling
Easy to use parameters to set the conversion operation and scaling, no need to create a dedicated program.
Therefore, it is helpful to reduce the development cost of the program and to reduce the program capacity.
High speed data sampling is not affected by the scan time.
The analog input module has the function of recording, which can be used to collect the analog quantity input data in the industrial application.
Can continuously collect data in a set period, each channel can store up to 10000 points of the recorded data.
In addition, the state of the state of any time and data in the program can be changed as a trigger,
To stop collecting data. The analog quantity input data can be stored and maintained before and aafter the trigger state through the function,
Easy to determine the occurrence of the phenomenon and the collection of test data R120SFCPU-SET datasheet. Such as motor testing equipment used in this function.
Control instructions from a programmablee controller to a transducer and a power meter transmission test mode,
At the same time, the test data of the test motor is collected at the same time R120SFCPU-SET datasheet.