When the power supply capacity exceeds the power supply capacity of the inverter or the need to improve the power factor, it is required to connect the AC reactor.
Please according to the maximum capacity of heavy load and light load rated conditions suitable for motor to select option. Specification: three phase 200V 3G8F7-CLK53-E PDF.
Power: 90KW.
Maximum output voltage: three phase AC200 ~ 240V (input voltage correspondence)
3G8F7-CLK53-E
Rated voltage: three phase 240V ~ 50/60Hz AC200.
Weight: about 108kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive.
The high functional specifications are concentrated in the compact 3G8F7-CLK53-E PDF.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function. ISA bus: support software.Box protection class: plastic, IP00 3G8F7-CLK53-E PDF.
Terminal size: M4.
Line diameter: 2 square mm, 3.5 square mm.
Weight: 0.7kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Function name: 3 phase 200V.
Power: 5.5KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 3.3KG.
Dimension (w * h) 260mm *:140.
Outline dimension (deep):155mm.
Mechanical automation concept 3G8F7-CLK53-E datasheet.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 00 3G8F7-CLK53-E datasheet. 5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H.