Commonly used with other Communications Units.Model: CPM2A-60CDT1-D. Power supply: DC power supply.
Output type: Transistor sourcing.
Inputs points: 36 points.
Outputs points: 24 points.C500-CP Special I/O Unit Cam Positioner Unit C500-CP131.Model : C500-NC112.
1-axis control.CV500-BS CPU Bus Unit BASIC Unit CV500-BSC51 CJ1G-CPU44P PDF.
RS-232C: 1 port.
GP-IB: 1 port.
(w/o EEPROM).Unit type: CS1 Special I/O Units
CJ1G-CPU44P
Product name: Analog Input Unit (100 mV).
Input points : 8 inputs.
Signal range: 0 to 100 mV, ±100 mV.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE CJ1G-CPU44P PDF.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling CJ1G-CPU44P PDF.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 8 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 4 to 20mA;
1/4,000 (Settable to 1/8,000) *2.
Conversion period: 1 ms/point,
(Settable to 250 μs/point)*2.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S.
External connection: Removable terminal block.
External power supply: 244 VDC +10% -15%, 170mA max CJ1G-CPU44P datasheet.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.14A; 24V, 0.17*3.
Standards: UC1, N, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CJ1G-CPU44P datasheet.
Analog Output Units for converting binary ,