Unit type: CJ1 Basic I/O Units.
Product name: Quick-response Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block CP1E-N30DR-A PDF.
No. of words allocated: 1 word.
Current consumption: 5V, 0
CP1E-N30DR-A08A; 24V, --.
Standards: UC1, N, L, CE.
Capture Input Signals Shorter,
Than the Cycle Time.
This Input Unit can read pulse inputs that,
are shorter than the cycle time of the CPU Unit. UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 µ CP1E-N30DR-A PDF. s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Model: CPM2C-8ER. Units with relay outputs only.
I/O terminal block.
Outputs: 8 outputs.
Input type: 24 VDC.
Output type: relay.Model: C200HW-COM04-V1.
Specifications: Communications port for the Controller Link, SYSMAC LINK Units, one RS-232C port, and a protocol macro function CP1E-N30DR-A PDF. Inputs: 8I/O link input bits.
Outputs: 8I/O link input bits.Connects Power Supply Adapter and SYSMAC NET Link Unit.
Included with C200H-APS01.UM: 31.2K words.
DM: 6K words.
EM: 6Kx3 banks(18K) words.
Instruction processing time (basic instructions): 0.1 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Specifications: Without clock (see below). Power supply: AC power supply.
Output method: Relay output.
Inputs points: 6 points.
Outputs points: 4 points.Name: e-CON Connectors.
Specifications: Inputs/Outputs;
16 inputs /16 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can bbe reduced CP1E-N30DR-A datasheet.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CP1E-N30DR-A datasheet.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.