CPU Unit: CP1L-L CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Transistor output (sourcing);
Inputs, 12; Output, 8 CP1E-N30DT-A PDF.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet
CP1E-N30DT-A
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams CP1E-N30DT-A PDF. Provided with SYSMAC LINK Unit.I/O capacity: 512 pts (2, 048 max. with remote I/O).
Execution time: Basic: 0.15 µs min.Special: 0.6 µs min.
C200HS-CPU03-E CPU
High Performance, Small Rack Style
The C200HS-CPU01-E and C200HS-CPU03-E controllers offer some of the same basic functionality as models C200H-CPU21-E/CPU23-E CP1E-N30DT-A PDF.
These controllers have added capabilities ideally suited for high speed machine control,
which includes larger memory,
larger instruction set,
and increased speed.Output type: Transistor sinking.
Inputs points: 24 points OMRON OPERATION MANUAL.
Outputs points: 16 points.Unit type: CS1 Special I/O Units.
Prroduct name: Isolated-type,
Resistance Thermocouple Input Units CP1E-N30DT-A Manual.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block OMRON OPERATION MANUAL.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON OPERATION MANUAL.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CP1E-N30DT-A OPERATION MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N30DT-A Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.