C500-DA Special I/O Unit Analog Output C500-DA103.
Output: 4 pts.
Specification: -10~+10V.Model: C500-BC081(3G2A5-BC081).
8 slots(3 linkable slots).
Product name: E@@S type CPU Units with 10 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 6; Outputs, 4;
Output type: Transistor (sinking) CS1W-OC201 PDF.
Program capacity: 2K steps.
memory Data capacity: 2K words.
External powersupply(24 VDC): --
CS1W-OC201
Current consumption: 5 V, 0.11A; 24 V,--.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CS1W-OC201 PDF. C500-CT/3G2A5-CT Special I/O Unit High-speed Counter Unit 50 kcps 1 pts C500-CT012(3G2A5-CT012).Model: C500-CN331.
Cable length: 30 m.
Programming Console Connecting Cable.
For extension and connection of FIT of FIT.
Unit classification: CJ1 Special I/O Units.
Product name: Isolated type DC Input Units CS1W-OC201 PDF.
Input points: 2 inputs.
Signal range selection: DC voltage:
0 to 1.25 V, -1.25 to 1.25 V, 0 to 5 V,
1 to 5 V, -5 to 5 V, 0 to 10 V, -10 to 10 V,
±10 V selectable range DC current:
0 to 20 mA, 4 to 20 mA.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 24V, 0.09A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost cann be reduced CS1W-OC201 datasheet.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1W-OC201 datasheet.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.