Actuator: Roller lever (resin roller).
Conduit openings: M20.
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts D4C-1720 PDF.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever
D4C-1720
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13) D4C-1720 PDF.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Type: Welding / wire type, with right column.
Drive rod: rod type Shibai leaf.
Terminal specifications: with wire, under the lead.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment D4C-1720 PDF.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Actuator: Roller plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Release key type: Special release key.
Indicator: Green.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits andd two monitor contacts provide an,
array of monitoring patterns D4C-1720 datasheet.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas. D4C-1720 datasheet.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection.