Ratings: 5 A.
Actuator: Hinge lever.
Terminals: Molded lead wires (300 mm).
Contact form: SPDT.
Sealed Miniature Basic.
Switch Conforms to IP67.
(Excluding the terminals on terminal models).
Use of epoxy resin assures stable sealing, making.
this switch ideal for places subject to water spray D4N-1226 PDF.
or excessive dust.
V-series internal mechanism assures high.
precision and durability
D4N-1226 The mounting is the,
same as of the V models.
Ideal for automobiles, agricultural machines,
large-scale home appliances, and industrial,
equipment, which require high environmental resistance. Actuator: One-way roller arm lever (horizontal).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO(Snap-action) D4N-1226 PDF.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4N-1226 PDF.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Roller lever, high sensitivity.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cablle lengths of 3 and 5 m available on standard models D4N-1226 datasheet.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4N-1226 datasheet.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)