Terminal type: Enclosed-terminal Models.
Protective tubing length L: 75cm.
Protective tubing diameter D (mm): 6.4 dia.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E2B-M12KS02-M1-C2 PDF.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal
E2B-M12KS02-M1-C2 Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling E2B-M12KS02-M1-C2 PDF.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E2B-M12KS02-M1-C2 PDF.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Sensing distance: (See note 2.)0 to 3.5 mm(pressed position) (See note 1.).
Sensing method: Pushbutton.
Operation mode: OFF with no load.
Cable length: 1 m (robot cable).
Model: PNP output .
Using a pushbutton enables,
accurately detecting difficult-to-detec objects.
Conforms to standards for semiconductor FOUP cassettes to ena,
accurately detecting FOUP cassettes without being affected by the,
material, color, or reflectance of the bbottoms of the cassettes E2B-M12KS02-M1-C2 datasheet.
Thin design enables mounting in a wider range of applications, e.g.,
on transfer arms.
Increased visibility with 4-direction indicator.
Optical detection of actuator operation provides a lonng life,
(mechanical life: 5 million operations min E2B-M12KS02-M1-C2 datasheet. ).
Models available with PNP or NPN output.
Models are available with very flexible robot cable.