Control terminal block: Screwless clamp terminal block.
Type: Standard.
Capacity: 45 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control G3J-205BL AC100-240 PDF.
RS-485 communications to set manipulated variables and,
monitor load current
G3J-205BL AC100-240
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified G3J-205BL AC100-240 PDF. EtherCAT-compatible encoder input terminal which,
enables high-speed and accurate control.
Two counter function available.
Pulse count within 32 bit range.
Maximum input pulse frequency of 4MHz,
(Line driver input after quadrature).
High-speed network EtherCAT enables,
high-speed and accurate control.
Selectable two input types:
Open collector input and line driver input.
Built-in two external latch inputs,
and one reset input G3J-205BL AC100-240 PDF.
Selectable node address settings: setting with,
rotary switches and setting on tool software.
Detachable screw terminal will facilitate,
the maintenance work. Unit: Connector model.
I/O classification: Digital input.
Internal I/O common: PNP (- common).
I/O points: 16.
I/O connections: Fujitsu connector.
Power supplyvoltage: 24 VDC.
I/O specification: DC/transistor.
Digital I/O Units Compatible with MULTIPLE I/O TERMINAL,
Terminal block, connector, and high-density connector,
models are available.
The circuit block of the terminal block model can be,
mounted or dismounted for ease of maintenance without,
disconnecting the wires.
DIN track mounting. Name: Slice I/O Units; Digital I/O Units.
Specifications: 4 inputs NPN.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reducced G3J-205BL AC100-240 datasheet.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee G3J-205BL AC100-240 datasheet.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.