Isolation: Phototriac coupler.
Zero cross function: Yes.
Indicator: Yes.
Rated output load: 30 A at 180 to 400 VAC.
Rated input voltage: 12 to 24 VDC.
Extremely Thin Relays Integrated with Heat Sinks.
Downsizing achieved through optimum design of heat sink.
Mounting possible via screws or via DIN track G3J-211BL DC12-24 PDF.
Close mounting possible for linking terminals.
(Except for G3PA-260B-VD and G3PA-450B-VD-2
G3J-211BL DC12-24)
Applicable with 3-phase loads.
Replaceable power element cartridges.
Comply with VDE 0160 (finger protection),
with a dielectric strength of 4,000 V between input and load.
Certified by UL, CSA, and VDE (reinforced insulation). Input terminals: Compact slotted screw terminals (detachable) G3J-211BL DC12-24 PDF.
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps G3J-211BL DC12-24 PDF.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Safety outputs *3: Instantaneous, 2(Semiconductor);
OFF-delayed*2, 2 (Semiconductor).
Auxiliary outputs *4: 2(Semiconductor).
Logical AND connection: Inputs, 2(Semiconductor); Outputs, 2(Semiconductor).
No. of input channels: 1 or 2 channels.
Max. OFF-delay time *1: 15 s.
Rated voltage: 24 VDC.
Terminal block type: Screw terminals.
Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or complete control system setup.
Solid-state ouutputs (excluding Expansion Units) G3J-211BL DC12-24 datasheet.
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unnit joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set G3J-211BL DC12-24 datasheet.
-Two logical AND connection inputs.