Standard certification: No.
Action indicator: No.
Applicable load of output: DC4 3A ~ 48V.
Input rated voltage: DC4 ~ 24V.
Insulation: photo coupler.
Zero trigger function: No.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type).
Achieved UL, CSA, EN (VDE certification) standard certification G3J-S Series PDF. (type -VD)
Socket terminal type of same size with MY (2 pole type)
G3J-S Series
A model with an action indicator to check the status of the input. Terminal (wire connection): Screw terminal.
Applicable output load: AC load.
Zero cross function: No.
Rated input voltage: AC 200V.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay G3J-S Series PDF.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability G3J-S Series PDF.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Input capacity: 32 points.
Rated current (ON current): 0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max. (0.5 ADC,
between each output terminal and the G terminal).
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Output device supply current: 100 mA/point.
Unit power supply current consumption: 100 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 210 g max.
Expansion functions: No.
Output handling for communications errors:
Select either hold or clear.
Short-circuit protection function: No.
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminal is provided for,
each connector G3J-S Series datasheet.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswitch and with tool software G3J-S Series datasheet.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.