LK166
Home >> Products >> OMRON >> Power/other peripheral devices >> Power / equipment protection equipment >> Protective equipment for equipment >> K8AK-PH Series OMRON K8AK-PH Series

K8AK-PH Series OMRON K8AK-PH Series

Brand: OMRON
Name: Phase-sequence Phase-loss Relay
Model: K8AK-PH Series
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON.
Supports phase loss detection when the motor is operating.
5 A (resistive load) at 250 VAC, DPDT x 1.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors.

Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage OMRON K8AK-PH Series.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K8AK-PH Series
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON K8AK-PH Series. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Power ratings: 240 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 24 V.
Output current *1: 10 A OMRON K8AK-PH Series.
Cost-effective Single Phase Power Supply.
Universal input and Safety standards.
for worldwide applications.
Space-saving Compact Design.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Operation temperature range: –25 to 60 °C.
Compact Dimension for small space.
Flexible installation by special mounting brackets.
Safety standards:
UL508/60950-1, CSA C22.2 No.107.1/60950-1.
EN50178, EN60950-1.
EMS: Conform to EN61204-3.
EMI: EN55011 Class A.
Three years Warranty. Collection housing: square type shell embedded ADR shell.
Purpose: high voltage non grounded system; high voltage PC (reactor) grounding system.
Digital ground directional relay K2GS-H type,
Can measure the zero phase current, zero phase voltage of the digital DGR.
And automatic test equipment can be used to testt the relay conveniently K8AK-PH Series.
Can be set for the coordination of a small number of hours to adjust the time.
Improve reliability by monitoring function at any time.
LED can be used to confirm the occurrence of anomalies.
The forced actionn of the experimental switch can be easily recognized K8AK-PH Series.
Based on the DIN standard size, the depth is only small size 88.5mm. (except for terminal units)


...More relevant models >>>>
Related model