Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application.
Four types of Expansion I/O Units for hard-wired diagnosis or standard signals.
Clear diagnosis and monitoring via Ethernet or Serial connection G6B-47BND PDF.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats
G6B-47BND
Easy design, verification, standardization and reusage of,
safety control by unique programming software.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified. Classification: Output.
Internal I/O circuit common: NPN (+ common).
Rated voltage: 24 VDC.
Reduces Wiring while Providing I/O G6B-47BND PDF.
Flexibility.
Mount I/O relays and I/O SSRs freely.
Electric-shock preventive (finger-touch protection) terminal.
block incorporated conforming to VDE 0160.
Connects to the PC and SBC easily via a connector.
DIN track mounted.
I/O Block conforming to VDE 0160. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC G6B-47BND PDF.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 45 A, 100 to 240 VAC.
Number of pole: 2.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
Surge pass protection improved surge dielectric strength,
for output currents. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIN Track mounting types mount to DIN Track.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification). Number of phase: Single-phase.
Control terminal block: Terminal block with small slotted screws.
Type: Constant current.
Capacity: 20 A, 100 to 240 VAC.
Heater burnout detection: Yes.
Communications: Yes.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control. G6B-47BND datasheet.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control G6B-47BND datasheet.
Application with various loads: constant load resistance,
variable load resistance.