Classification: Equipped with operation indicator and diode to absorb coil surge.
Contact form: 4PST (long-life).
Mounting method: DIN Track or screw mounting.
Terminals: Phillips screw terminal.
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal Relay with 4 Independent.
Outputs.
5 amps of power.
Sealed plastic construction used for relays.
Easy wiring with separated input/output terminals.
(except for high-reliability models).
(except for high-reliability models).
VDE certification for G6B-4BND/47BND/48BND for 12/24 VDC.
DIN Track mounting, and screw mounting models are available.
Control terminal block: Screwless clamp terminal block.
Type: Standard.
Capacity: 60 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or optimum cycle control OMRON G6B-47BND.
RS-485 communications to set manipulated variables and,
monitor load current
G6B-47BND
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,
and constant-current control.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified OMRON G6B-47BND. Action mode alarm contact: lock, a contact.
Category: no auxiliary contact.
Relay number: 2.
Relay circuit unit suitable for centralized alarm device of various control circuits.
MYA combination of multiple MY4 micro power relay, with all kinds of alarm function.
Small, socket type, so it can effectively use the space, repair, maintenance and other operation is simple and convenient.
By use, roughly divided into 4 types, to adapt to the full range of models OMRON G6B-47BND.
Lloyd standard certified products (MYA-LA12, -LB12). Input terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler G6B-47BND OMRON.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note G6B-47BND OMRON. ): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters G6BB-47BND OMRON G6B-47BND.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinals (detachable), or compact slotted,
screw terminals (detachable) OMRON G6B-47BND.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.