Item: Basic model.
DPDT: Rated voltage, 24 VAC, 50 VAC, 100/(110) VAC,
200/(220) VAC, 12 VDC, 24 VDC, 100 VDC.
Unique Ratchet Mechanism Assures Positive.
Alternate Transfer/Switching Operation.
Each contact in the double-pole contact mechanism performs.
alternate make-brake operation at each pulse input and is thus GRT1-OD4-1 PDF.
ideal for alternate operation or transfer/switching operation of a motor
GRT1-OD4-1
Positive operation is assured due to the unique ratchet mecha nism.
Satisfies dielectric strength of 2,000 VAC.
Low power consumption.
(AC: approx. 6.4 VA; DC: approx. 3.9 W). Category: Standard type.
Ontology: UL standard certification type and insert terminal type.
Pole number: 4 pole.
Timing control for 4 pole of high contact reliability GRT1-OD4-1 PDF.
By way of realizing high quality Tika delay, service life and stability.
And MY4 Series in the installation of a swap.
Action display mechanism with action of confirmation.
There are motion display lights built products. Mounting type: W-bracket(see note).
Contact form: 4PST-NO.
Screw terminals.
A High-capacity, High-dielectric-strength,
Multi-pole Relay Used Like a Contactor GRT1-OD4-1 PDF.
Miniature hinge for maximum switching power for motor loads,
as well as resistive and inductive loads.
No contact chattering for momentary voltage drops up to 50%,
of rated voltage.
Withstanding more than 4 kV between contacts that are differ,
ent in polarity and between the coil and contacts.
Flame-resistant materials (UL94V-0-qualifying) used for all in,
sulation material.
Standard models approved by UL and CSA.
Structure: single stable type.
Contact structure: 1a.
Structure: high flux protection.
Coil rated voltage: DC18V.
Voltage resistant 10kV 1 pole 3A open close small relay.
High power electromagnetic loop is used to achieve high sensitivity (200mW).
Small relays, but can ensure the impact resistance of 10kV. Number of phases: Three-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Type: Externally attached heat sinks.
Applicable load: 15 A, 200 to 480 VAC.
Number of pole: 3.
Compact, Slim-profile SSRs with Heat Sinks.
Solid State Contactors for Three-phase.
Heaters Reduced Installation Work.
with DIN Track Mounting.
RoHS compliant.
SSurge pass protection improved surge dielectric strength,
for output currents GRT1-OD4-1 datasheet. (OMRON testing).
Slim design with 3-phase output and built-in heat sinks.
DIN Track mounting types and screw mounting types are available.
All DIIN Track mounting types mount to DIN Track GRT1-OD4-1 datasheet.
(applicable DIN Track: TR35-15Fe (IEC 60715)).
Conforms to UL, CSA, and EN standards (TÜV certification).