LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON H3YN-4-Z-B datasheet PDF

OMRON H3YN-4-Z-B datasheet PDF

Brand: OMRON
Product model: H3YN-4-Z-B
Name: Solid-state Timer
Sort: PDF datasheet
File language: English
File size: 6.53MB
Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H3YN-4-Z-B PDF H3YN-4-Z-B
External connections: 11-pin socket.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Transistor output(SPST) H3YN-4-Z-B PDF.
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Supply voltage: 24 to 230 VAC (50/60Hz)/24 to 48 VDC.
Control output: Contact output: SPDT (time-limit output SPDT).
Input type: No-input available.
Operating mode(see note): Eight multi-modes: Four multi-modes: A, B2, E, J.
Model: Screw terminal type.
Eight operating modes (H3DS-M) and four operating modes,
(H3DS-S) cover a wide range of applications H3YN-4-Z-B PDF.
A wide time setting range of 0.10 s to 120 h.
Two LEDs indicate power and relay status respectively. Installation method: surface mount, embedded mounting (common).
Action function: 8 multi-function action (A, B, C, D, E, F, G, H,).
Action mode / reset mode: time limit action / auto reset / external reset.
Set lock mechanism.
External connection mode: 11P socket.
Time limit contact: 1c.
Instantaneous contact: No.
1 timer to achieve AC/DC free power,
8 action functions 0.1 seconds to 9990 hours.
Through time display windows wide, eye-catching.
Free power mode using AC24 ~ 240V/DC12 ~ 240V.
And the DC specification does not have to specify the polarity.
8 action functions can be selected by the action function switch.
Set by time setting switch and time unit switchType: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A-2: Power ON Delay I, b: Repeat ccycle 1,
E: Interval, Z: ON/OFF-duty-adjustable flicker, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1 H3YN-4-Z-B datasheet.
External connections: 8-pin socket.
Input: None.
Output: Contact output (time-limit SPDT + instaantaneous SPDT),
Models with instantaneous contact outputs H3YN-4-Z-B datasheet.
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry.
Related products
OMRON
Solid-state Timer
H3YN-41-B
OMRON Solid-state Timer H3YN-41-B
Supply voltage: 24, 100 to 120, 200 to 230 VA
OMRON
Solid-state Timer
H3YN-4-Z-B
OMRON Solid-state Timer H3YN-4-Z-B
Supply voltage: 24 VDC. Time-limit contact:
OMRON
Solid-state Timer
H3YN-4
OMRON Solid-state Timer H3YN-4
Supply voltage: 24, 100 to 120, 200 to 230 VA
OMRON
Solid-state Timer
H3YN-41-Z
OMRON Solid-state Timer H3YN-41-Z
Supply voltage: 24 VDC. Time-limit contact: