Preset stage: 3-stage setting.
Nameplate lettering: English.
Nine Built-in Counters/Timers to.
Measure Equipment Operating.
Cycles and Times and Forecast.
Maintenance Timing.
Provides up to nine counters or accumulative timers.
(Counter and timer functions can be used at the same time.)
Individual forecast outputs to indicate maintenance timing H5CN-YAN PDF.
Pre-forecast display and machine stoppage output provided
H5CN-YAN
IP54 oil-proof type at setting area for resistance to oil and water.
Separate digit keys to easily change settings.
Compact, short-body: 72 × 72 × 79 mm (DIN).
Key protection function prevents incorrect operation.
Multiple outputs: NPN/PNP.
Directly connectable to 2-wire DC sensors H5CN-YAN PDF.
Complies with UL and CSA. Count input: No-voltage input.
Display: 7-segment LCD.
Total counter: Max. counting speed; 1 kHz.
Dedicated for use on PCB.
Total Counters and Time Counter available. External power supply: 12 VDC.
Output type: Contact and NPN transistor output.
Supply voltage: 24 VAC/12 to 24 VDC.
2-stage.
DIN 72 × 72 mm Multifunction Counter with a,
Bright, Easy-to-view, Negative Transmissive LCD H5CN-YAN PDF.
Highly visible display with backlit transmissive LCD.
Selectable display color (red/green) enables checking output status at a distance.
Easy operation with a key for each digit.
Perform all basic settings with a DIP switch.
Provides a total and preset counter, batch counter, dual counter,
and tachometer (See note.).
Wide range of inputs accepted for NPN/PNP inputs (multi-inputs) and,
2-wire DC sensors.
Complies with UL, CSA, and CE marking.
Degree of protection: IP54 equivalent (front section only). Operating modes: Star-delta Timer.
Supply voltage: 24 to 240 VAC/DC.
Control output: Contact outputs Delta circuit: SPDT, Star circuit: SPDT.
Set two time ranges between 1 and 120 s with one Timer.
Models with 240 to 440-VAC power supply added to series. Output: Contact.
Supply voltage: 100 to 240 VAC (50/60 Hz)/100 to 125 VDC;
24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-input available.
Time range: 0.1 s to 600 h.
Operating mode(See note 2): Five multi-modes: A, B,B2, E, J (Power supply start).
Output: Transistor(Photocoupler).
Supply voltage: 24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: No-voltage input.
Time range: 0.05 s to 300 h.
Operating mode (See note 2): Eight multi-modes: A, B, B2, C, D, E, G, J.
Multiple Operating Modes and Multiple Time.
Ranges. DIN 48 x 48-mm Multifunctional Timer.
A wide AC/DC power supply range greatly reduces the number,
of timer models kept in stock.
A wide range of applications with multiple operating modes,
eight modess for 11-pin models and five modes for 8-pin models H5CN-YAN datasheet.
Ecological design with reduced current consumption.
Easy sequence checking with instantaneous outputs for a zero set value.
Length of 75 mm or less when panel-mounted with a P3G-08,
Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC),
PNP input models available H5CN-YAN datasheet.
Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking.