Count input: PNP/NPN universal DC voltage input (4.5 to 30 VDC).
Display: 7-segment LCD.
Max. revolutions displayed (applicable encoder resolution):
1000 s–1 (1 pulse/rev.), 1000 min–1 (60 pulse/rev.); Black body.
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000 H5S-YA4-X PDF. 0 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1
H5S-YA4-X Type: H7CX-R Series.
Classification: Tachometer.
Configuration: Tachometer.
External connections: 11-pin socket.
Settings: 1-stage(2 inputs and outputs).
Display digit: 6 digits.
Outputs: Contact output (SPDT + SPST).
Power supply voltage: 12 to 24 VDC/24 VAC H5S-YA4-X PDF.
Ultra-compact Counter Provides More,
Complete Functionality.
Basic Features.
Short body with depth of only 59 mm (for 12 to 24-VDC Models with,
Screw Terminals).
Better readability with character height of 12 mm on 4-digit models,
and 10 mm on 6-digit models.
The present value display characters can be switched between red,
green, and orange.
Safety and Reliability H5S-YA4-X PDF.
New set value limit and counter functions have been added.
Other Features.
Front Panel can be changed to white or light gray.
New models with two tachometer inputs and two tachometer outputs have,
been added to the series. Control cycle: Yearly.
Number of outputs: 2 circuits.
Mounting method: Surface mounting/track mounting.
Supply voltage: 24 VDC.
Easier, More Convenient Time Switches, with,
New 4-circuit Output and Yearly Models in,
Addition to 2-circuit Weekly Models.
Independent Day Keys provide easier operation.
Temporary holiday setting function makes it easy to turn OFF,
output for holidays and non-operating days.
Settings can be made even with the Time Switch turned OFF.
Test mode enables easy program checking.
Complies with EMC Directives, UL/CSA, and other safety standards.
Includes summer time (DST) adjustment.
Yearly models also offer automatic switching to DST.
Set value can be changed both upward and downward for speedieer setting H5S-YA4-X datasheet.
Integrated temperature compensation circuit helps keep,
accurate time over a wide temperature range. (See note 1.)
Includes time counter and total counter functions with alarm,
indicator. (See note 2.)
Bank functioon allows program switching by an external input H5S-YA4-X datasheet.
(See note 3.)
New 4-circuit output models with a compact, 72 × 72-mm DIN,
size added to the series.