Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K2CM-Q1L PDF.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out
K2CM-Q1L
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K2CM-Q1L PDF. Product: Tool for Replacing Dischargers.
Wide Range of Nozzles for Optimal.
Ionization.
A wide range of nozzle variations.
High-frequency AC method with excellent ion balance. Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three K2CM-Q1L PDF.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V AC/DC, 15 to 150 V AC/DC.
Supply voltage: 100-115 VAC.
Ideal for voltage monitoring for industrial.
facilities and equipment.
Monitor for overvoltages and undervoltages simultaneously.
Separate settings and outputs supported for overvoltages and,
undervvoltages K2CM-Q1L datasheet.
Manual resetting and automatically resetting supported by one Relay.
Pre-alarm Monitoring Mode.
Two SPDT output relays, 6 A at 250 VAC (resistive load).
Process control signal (0 to 10 V) and current splitter input ssupported K2CM-Q1L datasheet.
Output status can be monitored using LED indicator.
Input frequency of 40 to 500 Hz supported.
Inputs are isolated from the power supply.