OMRON K3HB-VLC-CPEC21 AC/DC24 datasheet PDF

Brand: OMRON
Product model: K3HB-VLC-CPEC21 AC/DC24
Name: Load sensor, mV instrument
Sort: PDF datasheet
File language: English
File size: 1.48MB
Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K3HB-VLC-CPEC21 AC/DC24 PDF.
Action determine the color, can switch the green / Red 2 kinds of color display K3HB-VLC-CPEC21 AC/DC24
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum measurable range from 10ms to 3200s.
6 measurement methods, including 2 pointsInput type: high speed response type K3HB-VLC-CPEC21 AC/DC24 PDF.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External power supply DC12V80mA.
Output type: linear; voltage; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
High speed, high precision measurement, determine the color display,
Can switch the green / Red 2 kinds of display colors K3HB-VLC-CPEC21 AC/DC24 PDF.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the starrt of operation K3HB-VLC-CPEC21 AC/DC24 datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-VLC-CPEC21 AC/DC24 datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Time interval table
K3HB-PPB-CPAC21 AC/DC24V
OMRON Time interval table K3HB-PPB-CPAC21 AC/DC24V
Input type: PNP input type. Event input term
OMRON
Load sensor, mV instrument
K3HB-VLC-CPBC21 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-CPBC21 AC100-240
Category: external supply 100mA DC10V. Input
OMRON
Temperature panel
K3HB-HTA-CPAC21 AC/DC24
OMRON Temperature panel K3HB-HTA-CPAC21 AC/DC24
Type of input: platinum resistance / thermoco
OMRON
Rotating pulse meter
K3HB-RNB-CPAC21 AC/DC24V
OMRON Rotating pulse meter K3HB-RNB-CPAC21 AC/DC24V
Input type: NPN/ voltage pulse input type. E