LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON K3HB-XVA-1 AC/DC24 datasheet PDF

OMRON K3HB-XVA-1 AC/DC24 datasheet PDF

Brand: OMRON
Product model: K3HB-XVA-1 AC/DC24
Name: Voltage and current panel meter
Sort: PDF datasheet
File language: English
File size: 1.90MB
Input type: DC current input.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K3HB-XVA-1 AC/DC24 PDF.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-XVA-1 AC/DC24
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviPower supply voltage: 100 to 240 VAC K3HB-XVA-1 AC/DC24 PDF.
Heater control method: Phase control Cyclic control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods K3HB-XVA-1 AC/DC24 PDF.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation timee,
is indicated from the start of operation K3HB-XVA-1 AC/DC24 datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeency, basic,
frequency, and load conditions K3HB-XVA-1 AC/DC24 datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Related products
OMRON
Voltage and current panel meter
K3HB-XAA-1 AC/DC24
OMRON Voltage and current panel meter K3HB-XAA-1 AC/DC24
Type of input: AC current input. Output type
OMRON
Temperature panel
K3HB-HTA-FLK1AT11 AC/DC24
OMRON Temperature panel K3HB-HTA-FLK1AT11 AC/DC24
Type of input: platinum resistance / thermoco
OMRON
Voltage and current panel meter
K3HB-XAA-FLK3AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XAA-FLK3AT11 AC/DC24
Type of input: AC current input. Output type
OMRON
Voltage and current panel meter
K3HB-XAA-L1AT11 AC/DC24
OMRON Voltage and current panel meter K3HB-XAA-L1AT11 AC/DC24
Type of input: AC current input. Output type