LK166
Home >> Download >> OMRON >> Catalog Download >> OMRON K8AB-AS3 AC100/115V datasheet PDF

OMRON K8AB-AS3 AC100/115V datasheet PDF

Brand: OMRON
Product model: K8AB-AS3 AC100/115V
Name: Single-phase Current Relay
Sort: PDF datasheet
File language: English
File size: 0.81MB
Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents and undercurrents simultaneously.
Separate settings and outputs supported for overcurrents and undercurrents K8AB-AS3 AC100/115V PDF.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) K8AB-AS3 AC100/115V
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
Two sets of SPDT output contacts, 5 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply K8AB-AS3 AC100/115V PDF. Input type: DC voltage input type.
Output type: linear; current; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K8AB-AS3 AC100/115V PDF.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet typeTime specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K8AB-AS3 AC100/115V datasheet.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AB-AS3 AC100/115V datasheet. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Related products
OMRON
Single-phase Current Relay
K8AB-AS3 AC200/230V
OMRON Single-phase Current Relay K8AB-AS3 AC200/230V
Measuring current: 10 to 100 A AC, 20 to 200
OMRON
Single-phase Voltage Relay
K8AB-VW2 AC100/115V
OMRON Single-phase Voltage Relay K8AB-VW2 AC100/115V
Measuring voltage: 1 to 10 V AC/DC, 3 to 30 V
OMRON
Single-phase Voltage Relay
K8AB-VS3 AC100/115V
OMRON Single-phase Voltage Relay K8AB-VS3 AC100/115V
Measuring voltage: 20 to 200 V AC/DC, 30 to 3
OMRON
Single-phase Current Relay
K8AB-AS1 AC100/115V
OMRON Single-phase Current Relay K8AB-AS1 AC100/115V
Measuring current: 2 to 20 mA AC/DC, 10 to 10