Model: C500-CE243.
Connection : Pressure welded.
FCN-367J024-AU/FModel: C500-CN531.
Cable length: 50 m.
Programming Console Connecting Cable.
For extension and connection of FIT of FIT CQM1H-SCB41 PDF.
Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet
CQM1H-SCB41
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction CQM1H-SCB41 PDF.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Model: C200H-IM211.
No. of inputs: 8 pts.
Input voltage: 12 to 24 VAC/DC, +10%/–15% CQM1H-SCB41 PDF.
Input current: 10mA, 24VDC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 8 pts.
Internal currentcon-sump-tion: C1000H-CP CPU 62 k words 1024 pts C1000H-CPU01-E.C500-RT SYSMAC BUS Remote I/O Master Slave Wired C500-RT201 OMRON System Manual.
Master station unit remote I/O.Unit type: CS1 Speciaal I/O Units CQM1H-SCB41 Manual.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: B, E, J, K, N, R, S, T, ±80mV.
Conversion speed: 150 ms/4 inputs OMRON System Manual.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON System Manual.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spaace compared,
with previous systems CQM1H-SCB41 System Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CQM1H-SCB41 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.