Product name: CS1 Expansion Backplanes.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 10 slots.
Mountable configuration units:
Basic I/O Units, CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No CS1W-SPU02-V2 PDF.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No
CS1W-SPU02-V2
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.23A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control CS1W-SPU02-V2 PDF. Name: e-CON Connectors.
Specifications: Outputs; 32 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CS1W-SPU02-V2 PDF.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON INSTRUCTION MANUAL. Output method: Relay.
Inputs: ---.
Outputs: 16.Control method: Semiclosed loop with automatic trapezoid or S-curve acceleration/decceleration CS1W-SPU02-V2 Manual.
Control output signals: Analog.
Controlled axes: 2 axes max.Model : CVM1-PRS21-V2 OMRON INSTRUCTION MANUAL.
For ladder.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Pulse Input Unit.
Input points : 4 pulse inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.20A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices OMRON INSTRUCTION MANUAL.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CS1W-SPU02-V2 INSTRUCTION MANUAL.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-SPU02-V2 Manual.
Parameters can be easily displayed and set in an,