Product name: CS1 CPU Backplane.
Specifications: For both CS/C200H-series Units,
Units cannot be mounted; 8 slots.
Appli cable CPU Unit: CS1 CPU Unit CVM1-CPU01-V2 PDF.
Basic I/O Units: CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, Yes;
C200H Group-2 High density I/O Unit, Yes.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, Yes.
CPU Bus Units: CS-series CPU Bus Unit, Yes
CVM1-CPU01-V2
Current consumption: 5V system, 0.11A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control CVM1-CPU01-V2 PDF. I/O points: 512 pts.
Program capacity(words): 15.2 K.
DM capacity (words): 6 K.
EM capacity (words): 6 K.
RS-232C port: YES.Model: CPM2A-60CDR-A. Power supply: AC power supply.
Output type: Relay.
Inputs points: 36 points.
Outputs points: 24 points.Supply voltage: 24 V DC.
Operating voltage range: 20 to 28 V DC CVM1-CPU01-V2 PDF.
Output capacitty: 30 W 5 V DC: 6 A CVM1-CPU01-V2 Manual. Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications nits.
Specifications:Communications Interface,
2 RS-422A/485 ports;
Communications functions,
The following functions can be,
selected for each port:
Protocol macro Host Link,
NT Links (1:N mode)Serial Gateway,
No-protocol Modbus-RTU Slave OMRON OPERATION MANUAL.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.38A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol OMRON OPERATION MANUAL. Name: e-CON Connectors.
Specifications: Inputs; 32 inputs; NPN;
With Short-circuit and,
Disconnected Line Detection OMRON OPERATION MANUAL.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost cann be reduced CVM1-CPU01-V2 OPERATION MANUAL.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CVM1-CPU01-V2 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.