Type: thermocouple type.
Adjustment mode: ON/OFF action or PID action.
Alarm: single alarm.
Output: relay output.
Digital universal dual display electronic temperature controller E5AC-CC4DSM-014 PDF.
DIN 48 * 48mm manual automatic tuning (Auto-tuning Manual) PID control.
Double alarm / single alarm and temperature resistance antibody species rich.
Relay / solid state relay (SSR drive) series.
To prevent misuse function
E5AC-CC4DSM-014Appearance: R-shaped.
Sensing method: Through beam (with slot).
Sensing distance: 5 mm (slot width).
Output configuration: Light-ON Dark-ON (2 outputs).
Connection method (Cable length): Pre-wired model with robot cable (1 m) E5AC-CC4DSM-014 PDF.
Output type: NPN.
Meeting Customer Needs with.
Ultra-compact Sensors that Mount.
with M3 Screws.
Mount using M3 or M2 screws.
Reliable sensing slot depth of 6.5 mm.
Indication of sensing window for easy confirmation of,
insertion depth.
Bright indicator for confirmation from many directions E5AC-CC4DSM-014 PDF.
Both light-ON and dark-ON outputs provided.
All models available with either standard cable or,
flexible robot cable.
Load short-circuit protection circuit provided. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black OMRON Advanced Type E5AC-CC4DSM-014 Manual.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2 OMRON Advanced Type.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure OMRON Advanced Type.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makees the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E5AC-CC4DSM-014 Advanced Type.
Through the infrared port can be carried out from the frront of the communication E5AC-CC4DSM-014 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.