Control output 1: voltage output.
Control output 2: relay output.
Auxiliary output: 2 points.
Communication mode: RS-485.
Heater break: 1.
Event input: - E5EC-CX4DSM-014 PDF.
Power supply voltage: 100 ~ 240VAC.
Resistance to environmental performance of the industry leader.
Sulfide gas, dust, condensation of the corresponding.
Environment specific temperature controller.
Temperature control performance outstanding
E5EC-CX4DSM-014
High contrast display screen.
Set simple, easy to operate. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 35 cm.
Lead wire type: Heat resistive E5EC-CX4DSM-014 PDF.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the termiinal E5EC-CX4DSM-014 PDF E5EC-CX4DSM-014 Manual. Size: M12 (Brass); Double; Unshielded.
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector OMRON Advanced Type.
Body length: Short.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. E32-D61-S type: environment resistant; heat resistant,
Specialty: heat resistant: 350,
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsName: Temperature Controller (See note 1 OMRON Advanced Type. ).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Voltage output (for SSRs).
Auxiliary output: Transistor output: 2 pts (sinking).
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4 OMRON Advanced Type. )Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5.): Thermocouple.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,,
changing terminal wiring E5EC-CX4DSM-014 Advanced Type.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communicatiions wiring not required between,
Units when mounted side-by-side E5EC-CX4DSM-014 Manual.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance.