Terminal (Wire connection): Screw terminal.
Classification: Standard.
Latching lever (Test switch): No.
Rated input voltage: AC, 100V.
Global standard size, low profile slim GRT1-OD8 PDF.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape
GRT1-OD8
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location) GRT1-OD8 PDF.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Cable with connector (1 to 3) /G79-_C-_-_.
L size: A, 2000mm; B, 1750mm; C, 1500mm GRT1-OD8 PDF.
Input use
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Terminal (wire connection): Screw terrminal GRT1-OD8 Manual.
Applicable output load: AC load.
Zero cross function: Yes.
Rated input voltage: AC 110V OMRON REFERENCE MANUAL.
Global standard size,
low profile slim I/O relay with width 6.2 mm,
slim I/O solid state relay.
Realized about 25% lower profile than conventional,
products, contributing to further miniaturization of the,
control panel.
Push-In Plus terminal blocks are used to save wiring work,
in comparison with conventional screw terminals OMRON REFERENCE MANUAL.
(Wiring time is reduced by 60%* in comparison with,
traditional screw terminals.).
No screw loosening means maintenance-free application,
realizing high reliability.
Hand-free structure that holds an inserted flat-blade,
screwdriver to achieve easier wiring work for stranded wires OMRON REFERENCE MANUAL.
Screw terminal is also stocked to meet the screw type needs.
Mounted relay or solid-state relay has a plug-in terminal.
that is difficult to bend at the time of exchange. Number of elements: 3.
Insulation method: Photocoupler.
Rated supply voltage: 100 to 240 VAC.
Applicable motor: 0.75 kW (4.8 A), 200 to 220 VACC GRT1-OD8 REFERENCE MANUAL.
Solid State Contactors That Can Drive 3-phase Motors Frequently,
and Achieve Harmonized Protection with Thermal.
Overload Relays.
Certified for UL and CSA.
Mount with screws or to DIN tracks.
Compact monoblock construction ((W: 80 × H: 100 × D: 100 mm) GRT1-OD8 Manual.
with a heat sink.
Snubber circuit and varistor are built-in.
Operation indicator.
Two-element models added to series.