LK166
Home >> Products >> OMRON >> Master slave station products >> CompoNet >> CompoNet Communications Unit GRT1-ID4-1 OMRON GRT1-ID4-1

CompoNet Communications Unit GRT1-ID4-1 OMRON GRT1-ID4-1

Brand: OMRON
Name: CompoNet Communications Unit
Model: GRT1-ID4-1
Name: Slice I/O Units; Digital I/O Units.
Specifications: 4 inputs PNP.
Standards: CE, UC1, L, N.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

Name: Clamp Terminal Blocks.
Specifications: Inputs; 8 inputs ; NPN; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON GRT1-ID4-1.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site GRT1-ID4-1
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. I/O classification: Input.
Internal I/O circuit common: NPN (+ common).
I/O points: 8.
Rated voltage: 24 VDC OMRON GRT1-ID4-1.
I/O rated voltage: 24 VDC.
Long-distance Communications Supported by SRT2 Models,
(Long-distance/High-speed Communications Selection).
Ultra-compact at 80 x 48 x 50 (W x H x D) mm for,
4-point and 8-point terminals and 105 x 48 x 50,
(W x H x D) mm for 16-point terminals.
Two independent power supplies can be used,
because the I/O terminals are insulated from the internal circuits OMRON GRT1-ID4-1.
DIN track mounting and screw mounting are both supported. Name: System Units; I/O Power Feed Unit.
Specifications: Use when the total current,
consumption of the I/O Power Supply exceeds 4 A,
or to make the I/O Power Supply a separate system GRT1-ID4-1 OMRON.
Standards: CE, UC, L.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet GRT1-ID4-1 OMRON.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error GRT1-ID4-1 OMRON. Input capacity: 32 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min. (between each in,
put terminal and the V terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the V terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0.5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 32 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 230 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 220 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors.
A common terminnal is provided for,
each connector GRT1-ID4-1.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswitch and with tool software OMRON GRT1-ID4-1.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.


...More relevant models >>>>