Input type: DC voltage input type.
Output type: communication; RS-232C; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K3HB-PNB-A1 PDF.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
K3HB-PNB-A1
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K3HB-PNB-A1 PDF.
External event input can be applied to a variety of measurement and identification situations.
DevSize: 30 × 80 × 78mm (W × H × D).
Power supply voltage: 100 to 240 VAC.
A compact converter that allows,
communications between RS-232C/USB and,
RS-422/485 devices. Ideal for industrial,
applications K3HB-PNB-A1 PDF.
Allows communications between RS-232C/USB (Universal,
Serial Bus) and RS-422/485 devices.
Applicable in FA environments: Has ppassed environment,
resistance tests equivalent to those for control devices K3HB-PNB-A1 Manual.
CE marking (except for USB).
UL/CSA certification (mark license recognition) OMRON Communications Manual.
Compact 30-mm-wide body supports both screw-mounting and,
DIN track mounting.
Operation either with or without echoback available.
Functionality to convert between USB and RS-232C,
communications added.
USB driver providing virtual communications port for USB,
communications is available OMRON Communications Manual. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element OMRON Communications Manual.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phaase control, and cyclic control K3HB-PNB-A1 Communications Manual.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-PNB-A1 Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).