LK166
Home >> Download >> OMRON >> Manual Download >> OMRON K3HB-VLC-EBCD1 Communications Manual PDF

OMRON K3HB-VLC-EBCD1 Communications Manual PDF

Brand: OMRON
Product model: K3HB-VLC-EBCD1
Name: Digital Temperature Controllers
Sort: Communications Manual
File language: English
File size: 1.84MB
Supply voltage: 24 VDC.
Input type: DC voltage, DC current, or PNP input.
Output type: Judgement output, 3 transistor outputs (PNP open collector);
Data transmission output, RS-485 K3HB-VLC-EBCD1 PDF.
1/32 DIN Digital Panel Meter for Downsizing.
Equipment and Control Panels.
Compact size: 48 x 24 x 82 (W x H x D).
Multi-input compatible: DC voltage/current, rotary pulse.
Two display colors (switchable): green/red K3HB-VLC-EBCD1
Selectable outputs.
CE marking and UL/CSA approval.
Splash-proof construction (NEMA4X: equivalent to IP66). Time specification: Inverse type.
Current setting range: 50 to 160 A.
Operating voltage: 100/110/120 VAC K3HB-VLC-EBCD1 PDF.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K3HB-VLC-EBCD1 PDF.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation K3HB-VLC-EBCD1 Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions OMRON Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Power supply voltage: 100 to 240 VAC OMRON Communications Manual.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 2.00 to 22.00 A.
A high-precision Heater Element OMRON Communications Manual.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control K3HB-VLC-EBCD1 Communications Manual.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreent relay or for motor or lamp loads K3HB-VLC-EBCD1 Manual.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
Related products
OMRON
Load sensor, mV instrument
K3HB-VLC-L1ET11 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-L1ET11 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-BBCD1 AC/DC24V
OMRON Load sensor, mV instrument K3HB-VLC-BBCD1 AC/DC24V
Category: external supply 100mA DC10V. Input
OMRON
Load sensor, mV instrument
K3HB-VLC-E-DRT1 AC100-240
OMRON Load sensor, mV instrument K3HB-VLC-E-DRT1 AC100-240
Category: external supply 100mA DC5V type. I
OMRON
Load sensor, mV instrument
K3HB-VLC-ET11 AC/DC24
OMRON Load sensor, mV instrument K3HB-VLC-ET11 AC/DC24
Category: external supply 100mA DC5V type. I