Rated input (See note 2.): 3-phase 3-wire mode, 3-phase 4-wire mode;
380, 400, 415, 480 VAC, 220, 230, 240, 277 VAC.
Ideal for monitoring 3-phase power supplies K3HB-VLC-L1ET11 PDF.
for industrial facilities and equipment.
Monitor overvoltages and undervoltages for three-phase 3-wire,
or 4-wire power supplies.
DIP switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
Two SPDT output relays, 6 A at 250 VAC (resistive load)
K3HB-VLC-L1ET11
Separate outputs possible for overvoltages and undervoltages.
World-wide power specifications supported by one Unit,
(switchable using DIP switch).
Relay status can be monitored using LED indicator K3HB-VLC-L1ET11 PDF. Ideal for Monitoring 3-phase Power Supplies.
for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor undervoltages, overvoltages, voltage asymmetry, phase,
sequence, and phase loss in three-phase three-wire circuits with one unit.
One SPDT output relay, 5 A at 250 VAC (resistive load) K3HB-VLC-L1ET11 PDF.
World-wide power specifications supported by one unit.
(SSet with a rotary switch K3HB-VLC-L1ET11 Manual. ).
Relay status can be monitored using LED indicator. Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Power supply voltage: 24 VAC/DC OMRON Communications Manual.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A).
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately OMRON Communications Manual.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply. Input type: PNP input type.
Event input terminal 5 points (HOLD, RESET) equipped with OMRON Communications Manual.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
BCD+ transistor: -- NPN open collector (5 bit output +HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Powwer supply voltage: AC/DC24V K3HB-VLC-L1ET11 Communications Manual.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of widde range of pulse interval time K3HB-VLC-L1ET11 Manual.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the most