Power ratings: 100 W.
Output voltage: 12 V.
Output current: 8.5 A.
Boost current: 12.8 A.
Newly Released High-capacity 240-W Models in S8EX-series Lineup SYSMAC-RA401L PDF.
Rated Output of 300 W for 200 VAC.
From 170 to 264 VAC.
New 240-W Models.
Lineup of models with 24-, 36-, and 48-VDC output.
voltages.
15-W, 35-W, 50-W, 100-W, and 150-W Models.
Lineup of models with from 5 to 48-VDC output
SYSMAC-RA401L
voltages.
All Models.
Approved standards:
UL60950-1, cUR CSA C22.2 No. 60950-1, EN 50178,
and EN 60950-1.
Lineup includes open-frame models, models with.
chassis, and models with chassis and covers.
Wide-range power supply: 100 to 240 VAC SYSMAC-RA401L PDF.
Complies with harmonic current standard in EN.
61000-3-2 (50-W to 240-W models).
The top class in industry for compact size.
Boost current output (some models excluded). Capacity: 480 W.
Input voltage: 100 to 240 VAC.
Output voltage: 24 V.
Maximum cutoff output current (per branch): 3 SYSMAC-RA401L PDF. 8 A.
Total output current: 20 A.
Number of output branches: 8 branch outputs.
Communications functions: None.
Parameter settings: Changeable.
A New Type of Power Supply That.
Provides Safety and Maintainability.
240- and 480-W power supplies with and digitall circuit,
protectors in a single package OMRON OPERATION MANUAL SYSMAC-RA401L Manual.
Each branch output tripping current value can be easily,
set at 0.1-A increments.
Startup and shutdown sequence control included.
Various monitor displays and alarms (output voltage,
output current, maintenance forecast monitor,
temperature) OMRON OPERATION MANUAL.
Conforms to UL Class 2.
Mounts to DIN Rail. Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 150W.
Output voltage: 12V.
Output current: 12.5A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device OMRON OPERATION MANUAL.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(except for the 300/600/1500W output terminals)
Supporrt finger touch protection to prevent electric shock SYSMAC-RA401L OPERATION MANUAL.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhen the fan is replaced by the customer SYSMAC-RA401L Manual. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)