I/O points: 512 pts.
Program capacity(words): 15.2 K.
DM capacity (words): 6 K.
EM capacity (words): 6 K.
RS-232C port: YES.Name: Two-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; PNP.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet C200H-ID211.
Branchinng is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction C200H-ID211.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error C200H-ID211.
Model: C200H-ID211.
No. of inputs: 8 pts.
Input voltage: 12 to 24 VDC, +10%/–15%.
Input current: 10mA, 24VDC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 8 pts OMRON C200H-ID211.
Internal currentcon-sump-tion: 10m1 axis, Pulse input. counting speed: 50 kcps. 5VDC/12 VDC/24 VDC.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 4 loops;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector PNP outputs (pulses) OMRON C200H-ID211.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers OMRON C200H-ID211.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. C500-CT/3G2A5-CT Special I/O Unit High-speed Counter Unit 50 kcps 1 pts C500-CT012(3G2A5-CT012).Type: Counter inputs, pulse outputs.
12 DC inputs: Yes.
Counter inputs: None.
Analog inputs: None.
8 transistor outputs: Yes.
2 pulse outputs: No.
2 analog outputs: No.Name: e-CON Connectors.
Specifications: Inputs; 8 inputs ; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site C200H-ID211.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.