C200H-OD215 OMRON Transistor Output Module C200H-OD215


Specifications: 16 Kwords with clock.Model: C200H-MD215.
No. of I/O pts: 16 inputs, 16 outputs.
Specifications: 24VDC.
Model: C200H-OD215.
No. of outputs: 32 pts.
Specifications: 24 VDC.Power supply: DC power supply.
Output method: Relay output.
Inputs points: 6 points C200H-OD215.
Outputs points: 4 points.CQM1-B7A Special I/O Unit 16 POIINT IN /16 POINT OUT CQM1B7A01.Model: CPM2C-10CDTM-D. CPU Unit: Units with 10 I/O points.
2 MIL connectors.
Inputs: 6 inputs.
Outputs: 4 outputs C200H-OD215.
Input type: 24 VDC.
Output type: sinking transistor.
Internal clock: --.Specification: Thermocouple input (K, J, L, T, R, S, B),
ON/OFF or advanced PID control,
manual op-eration,
transistor (NPN) output, 4 loops.Provided with SYSMAC LINK Unit.Name: Three-tier Screw Terminal Block C200H-OD215.
Specifications: Outputs; 8 outputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced OMRON C200H-OD215.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error OMRON C200H-OD215. Name: Heat/Cool Temperature Control Module.
Model: C200H-TV003.
Sensor: Thermocouple: R, S, K, J, T, E, B, N, L, U.
Control output: Current output(transistor output used for cooling outputs) OMRON C200H-OD215.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 4 loops;
Temperature sensor inputs: Thermocouple,
input (R, S, K, J, T, B, L);
Control outputs: Open collector PNP outputs (pulses).
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometerr,
PID control with 2 degrees of freedom,
and open collector output C200H-OD215. Can be used for backing up programs or auto-booting.C500-AD/3G2A5-AD Special I/O Unit Analog Input C500-AD003(3G2A5-AD003).
Input: 2 pts.
Specification: 0~+5V.