Model: C500-CE241.
Connection : Soldered.
FCN-361J024-AU Connector
FCN-360C024-J2 Connector coverUnit classification: CJ1 Special I/O Units.
Product name: Position Control Units,
(High Speed type).
Specifications; Control method/Control,
output interface: Pulse-train open-collector,
output with Pulse Counter Function;
Number of coontrol axes : 2 axes C200H-PS221.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.27A; 24V, --.
Standards: UC1, CE C200H-PS221.
Motion Control Capabilities with Unit,
Synchronization and Even Higher Speed.
Models are available with 2 or 4 axes,
and open-collector or line-driver outputs.
The CJ1W-NC214/NC414 have open-collector outputs,
and the CJ1W-NC234/NC434 have line-driver outputs C200H-PS221.
Control 2 or 4 Axes High-speed, high-resolution,
position control is possible for servomotors ,
and pulse motors, and even linear motors,
and direct drive motors.
Model: C200H-PS221.
Supply voltage: 120/240VAC.Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Unit with MECHATROLINK-II interface OMRON C200H-PS221.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications.
Direct operation by ladder programming.
Control mode: Position control,
speed control or torque control;
No OMRON C200H-PS221. of axes: 2 axes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.36A; 24V,--.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management.
Control Servos for up to 16 axes in,
a motion network with one Position,
Control Unit that supports MECHATROLINK-II OMRON C200H-PS221.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. Specification: Thermocouple input (K, J, L, T, R, S, B),
heater burnout alarm,
ON/OFF or advanced PID control,
manual operation,
transistor (PNP) output, 2 loops.A memory card suitable for Phoenix PCM+3.2 and one of thefollowing Bus Connection Units is required. No PC card is provided with the Unit.Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 8 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 26V, 0.06A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring. <
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems C200H-PS221.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.