Model : CV500-CPU01-EV1.
SFC / Ladder 512 (with RAM30K words, the top internal link).Model : C500-LK009-V1.
Maximum of 32 PCs can be linked.
Name: CS1D CPU Backplane.
Specifications: Applicable systems,
Duplex CPU, Dual I/O Expansion System only;
Number of Power Supply Units,
2 Units max CS1D-BC042D. (for duplex operation);
Number of I/O Units, 5 Units max.
(including the I/O Control Units).
Current consumption: 5V system, 1.20A;
26V system, --.
Standards: UC1, CE CS1D-BC042D.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables.Name: Host Link Module.
Model: C200H-LK101-PV1.
Communication ports: 1 fiber port.Output method: Relay.
Inputs: 24.
Outputs: 16.Model: C200H-MD501.
No. of I/O pts: 16 inputs, 16 outputs CS1D-BC042D.
Specifications: 5 VDC.C1000HF-CPUA1 Omron Programmable Control CPU C1000HF-CPUA1-V1.CPU Unit: CP1L-EL CPU Units with 20 Points.
Specifications: CPU type, Memory capacity: 5K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, DC power supply; Output method, Relay output;
Inputs, 12; Output, 8 OMRON CS1D-BC042D.
Standards: CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port OMRON CS1D-BC042D.
"CP1L-M" and "CP1L-L" has a standard-feature peripheral USB port.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection OMRON CS1D-BC042D.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 8 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
> Seven-segment Display on the Gateway Unit,
helps to detect errors on site CS1D-BC042D.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.

Related supply information