LK166
Home >> Supply >> DRT2-ID16 OMRON Transistor Remote I/O Terminals OMRON DRT2-ID16
Search
Information sort

DRT2-ID16 OMRON Transistor Remote I/O Terminals OMRON DRT2-ID16


Operation indicator: Without operating indication; Microload.
Ratings: 0.1 A at 125 VAC; 0.1 A at 30 VDC.
Actuator: Roller lever.
Cable length : 3m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models DRT2-ID16.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material DRT2-ID16.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers DRT2-ID16.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.) Type: 1-Conduit.
Contact configuration: Slow-action; 2NC OMRON DRT2-ID16.
Conduit opening/Connector: M20.
Multi-contact, Labor-saving,
Environment-friendly, Next,
generation Safety-door Switch.
Lineup includes three contact models with 2NC/1NO,
and 3NC contact forms and MBB models in addition,
to the previous contact forms 1NC/1NO, and 2NC OMRON DRT2-ID16.
M12-connector models are available, saving on,
labor and simplifying replacement.
Standardized gold-clad contacts provide high,
contact reliability.
Applicable to both standard loads and microloads.
Variety of metallic heads available OMRON DRT2-ID16.
Specifications: Inputs; NPN (+ common); 16 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating information DRT2-ID16.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier.

Related supply information